2 Operating A&D DataManagement 07/2011
2.4 Specifying the properties of the control components
© Siemens AG 2011 All Rights Reserved
2-86 SIMATIC A&D DataManagement Client - 07/2011
Contents of the backup
Checkboxes NCU, loadable compile cycles, PLC and PROFIBUS drives are
used to define which components should be the contents of the backup of the
SINUMERIK components. Every component can be backed-up independently
of the others. A dedicated archive file is generated for each component of the
backup.
If the NC does not contain any compile cycles or drive data, but the appropriate
selection was made, the following applies:
An alarm is only output to indicate that this component was not able to
be backed up if at least one additional component was successfully
backed up.
If a partial backup is not possible, because e.g. only compile cycles are
selected, then the backup is exited with error.
If an error other than "Data do not exist” occurs, then the backup is
always exited with an error.
Notice
If the M:N option is activated:
The backup options "Loadable compile cycles” and "PROFIBUS drives"
are grayed out.
If, during the backup, ADDM detects that the NC is an 840D sl, backup is
interrupted and an error message is output.
Option, Routing via agent
SINUMERIK can also be addressed via a computer with ADDM Agent in the
network using Routing via agent. To do this, the computer name or the TCP/IP
address of the Agent computer should be specified via which this component is
connected.
Notice
For "Routing via agent”, HMI Advanced is expected on the PCU 50!
Save only in the reset state
Caution
We recommend that data is only backed-up in the reset state. The reason for this
is that backups carried-out during production can result in data inconsistency!
This is the reason that the backup checkbox "Save only in the reset state" is set
as standard.
Max. no. of backups
The number of backups to be saved from ADDM is defined in the input field
"Max. no. of backups”. When saving, ADDM takes into account what has been
specified and saves a new backup separately. If the "Max. no. of backups” is
reached, data is saved in the oldest backup. This data is then overwritten. This
means up to a maximum of 99 backups can be backed-up in ADDM , also refer
to chapter 2.5.2.