2.4 Specifying the properties of the control components
© Siemens AG 2011 All Rights Reserved
SIMATIC A&D DataManagement Client - 07/2011
2-85
The "Properties of the SINUMERIK component" dialog box contains the
following information:
• Name:
Freely assignable component name (max.32 characters).
• Remarks:
Field for user texts that can be freely edited.
• Last comparison
Date and time that online data were last compared with offline data.
• -load
Date and time that data were last downloaded into the component.
• -backup
Date and time that NCU data were last backed-up.
Addressing
The NCU or PLC are addressed via the parameters set in HMI Advanced.
Caution
If, while a SINUMERIK is operational, data is changed either from the
SINUMERIK itself or from the operator.
In this case, a backup already started via ADDM may be ended with errors. The
reason for this is that the ADDM cannot access data. If a communications error
occurs, the backup must be unconditionally repeated otherwise the modified data
cannot be backed-up.
In order to backup (archive), load or compare an NCU, all channels must be in
the RESET state. If this is not the case, then this can result in inconsistent data. If
all of the channels are in the RESET state, then start with the backup operation.
The progress dialog box showing the NC backup operation is always shown. This
means that every operator can see that presently a backup is being made. If not
all of the channels are in the RESET state, then an error message is returned to
the calling ADDM Client and displayed.
If the backup task is controlled by the job, then the job is interrupted with error
state -2. This means that the job is repeated after a pre-set time. If the maximum
number of repeats has been reached and the NCU has still not been backed-up,
the job is terminated and the next time that it will be executed is calculated. In this
case, the NCU was not backed-up in the backup cycle that expired.
M:N
For M:N configurations, the "M:N controller” checkbox must be activated. This
defines which controls are to be accessed and the "Name of the controller” must
be entered in the appropriate input field.