7
STATUS DISPLAY SECTION (LOWER)
The lower “-” mark indicates a comparison result.
In the normal mode, it is illuminated when a setpoint output of an identical name is turned on. In the setpoint setting
mode, the “-” mark relevant to the value in the lower numerical display section blinks. Attach an accessory label
depending on the weighing mode.
< Normal Batching >
[FINAL]
Blinks while setting the final weight.
Normal batching —— Illuminated when the net weight is within a positive range.
[F. FALL]
Blinks while setting the free fall.
Normal batching —— Illuminated when the net weight is more than the final weight minus free fall.
Built-in-automatic program mode —— Illuminated during dribble flow.
[PRELIM]
Blinks while setting the preliminary.
Normal batching —— Illuminated when the net weight is more than the final weight minus preliminary.
Built-in-automatic program mode —— Illuminated during medium flow.
[OP PLM]
Blinks while setting the optional preliminary.
Normal batching —— Illuminated when the net weight is more than the final weight minus optional preliminary.
Built-in-automatic program mode —— Illuminated during full flow.
[OVER]
Blinks while setting the overlimit.
Illuminated when the net weight is more than the final weight plus overlimit.
[UNDER]
Blinks while setting the underlimit.
Illuminated when the net weight is less than the final weight minus underlimit.
[ZERO BAND]
Blinks while setting the zero band.
Illuminated when the gross weight is less than the zero band.
< Loss-in-weight >
Attach a label that has “OPTIONAL PRELIMINARY replaced by “FULL.” The other operations are the same as normal
batching.
[FULL]
Blinks while setting the full weight./ Illuminated when the gross weight is more than the full weight.