AD-8920 REMOTE DISPLAY INSTRUCTION MANUAL
(日本語の取扱説明書は反対面をご覧ください。
1. Introduction
The AD-8920 is a remote display that uses vacuum fluorescent display technology. It displays the weighing
data transmitted by an A&D manufactured weighing instrument using RS-232C or current loop. Applicable
weighing instruments (electronic balances/platform scales) are listed below. When the output connector of the
weighing instrument is of the DIN type, an optional DIN conversion cable is required.
What the package contains
Table 1 Applicable instruments and required options (As of August, 2007)
AD-8920 main unit
Using RS-232C Using current loop
Communication cable (Approx. 1 m)
Weighing
instrument
On instrument
On AD-892
0
On instrument On AD-892
0
AC adapter
AD-4212A/B None (D-SUB25) None Not applicable
EK-G,EW-G OP-03(D-SUB25) None OP-05(DIN7) OP-01
EK-H O
P
-03H
D-SUB25
)
None OP-05H
(
DIN7
)
OP-01
EK-i,EW-i None
(
D-SUB9
)
None Not a
pp
licable
Instruction manual (this leaflet)
ET-W O
P
-03W
(
D-SUB25
)
None OP-05W
(
DIN7
)
OP-01
FC-i None
(
D-SUB9
)
None Not a
pp
licable
FG OP-03
(
DIN7
)
OP-01 OP-05
(
DIN7
)
OP-01
Options (Sold separately)
FG-M/L OP-23
(
DIN8
)
OP-01 Not a
pp
licable
OP-01 DIN conversion cable
(Approx. 25 cm)
FP OP-03(D-SUB25) None
OP-03 or
OP-04
(
DIN7
)
OP-01
FS OP-03
(
DIN7
)
OP-01 Not a
pp
licable
F
X
-i None
(
D-SUB9
)
None Not a
pp
licable
Connection diagram
GH,HR-i None
(
D-SUB9
)
None Not a
pp
licable
GR None (D-SUB25) None Not applicable
GX,GF, GP,
G
X
-K
None (D-SUB25) None
OP-04 or
OP-06
(
DIN7
)
OP-01
HA-M OP-03
(
D-SUB25
)
None OP-03
(
DIN7
)
OP-01
HA-A OP-03(D-SUB25) None
OP-03 or
OP-04
(
DIN7
)
OP-01
HC-i OP-03
(
DIN8
)
OP-01 Not a
pp
licable
HF,HM OP-03(D-SUB25) None
OP-03 or
OP-05
(
DIN7
)
OP-01
HP OP-03(D-SUB25) None
Either one of
OP-03,OP-04,
OP-05,OP-06,
(
DIN7
)
OP-01
HR OP-03(D-SUB25) None
OP-03 or
OP-05
(
DIN7
)
OP-01
HV-G
HW-G
None (DIN8) OP-01 Not applicable
HX None (D-SUB25) None
OP-04 or
OP-05
(
DIN7
)
OP-01
2. Preparation
2-1. Setting the weighing instrument
Table 2 List of instrument settings
Item Setting Description
Data output mode Stream mode Outputs the weighing data continuously.
Baud rate 2400b
p
s or 600b
p
s AD-8920 reco
g
nizes the baud rate automaticall
y
.
Len
g
th
,
Parit
y
bit 7 bits-even
,
7 bits-odd
,
or 8 bits-none AD-8920 functions correctl
y
with an
y
one of those listed.
Sto
p
bits 1 bit or 2 bits AD-8920 functions correctl
y
with either one.
Terminato
r
<CR> or <CR><LF> AD-8920 functions correctl
y
with either one.
Data format A&D standard format
CTS control No control of CTS
,
RTS
Out
p
ut
(
hardware
)
RS-232C or current loo
p
AD-8920 reco
g
nizes the out
p
ut mode automaticall
y
.
Note) The available items depend on the weighing instrument. (An item is not available when the setting is fixed.)
For a detailed description of the settings, refer to the instruction manual of each weighing instrument.
2-2. Connecting the AD-8920
1.Confirm that the AC adapter is of the correct type. 2.Refer to the Table1 shown above to connect the
communication cable correctly. Use the OP-01 DIN conversion cable when the output connector on the
weighing instrument is of the DIN type. 3.Refer to the connecting diagram shown above to connect the
AD-8920 to the weighing instrument by the communication cable.
D-SUB9/D-SUB25 output
Weighing
instrument
Communication cable
AC adapter
AD-8920 main unit
Przeglądanie stron 2
1 2 3 4

Komentarze do niniejszej Instrukcji

Brak uwag