Value in PointValue (1) = Zero Band.
Change Code
Description of this command:
Allows you to set the Code Number.
Methods used to run this command:
Digital Output
Number of points accepted by this command:
1
Meaning of the DriverP0 parameter:
Indicates the station address (0-9).
Meaning of the DriverP1 parameter:
10
Meaning of the DriverP2 parameter:
Indicates the Code Number (0-99).
Begin Batching
Description of this command:
Allows you to begin batching.
Methods used to run this command:
Digital Output
Number of points accepted by this command:
1
Meaning of the DriverP0 parameter:
Indicates the station address (0-9).
Meaning of the DriverP1 parameter:
11
Halt Batching
Description of this command:
Allows you to halt batching.
Methods used to run this command:
Digital Output
Number of points accepted by this command:
1
Meaning of the DriverP0 parameter:
Indicates the station address (0-9).
Meaning of the DriverP1 parameter:
12
Error messages
The following list shows the possible error messages that can be returned by the driver during a failed
communication in the 'Status' property.
[1005] DRIVER (Internal): Invalid driver stage
[1300] PROTOCOL (Timeout): No answer
[1410] PROTOCOL (Format): Invalid device id in response
[1426] PROTOCOL (Format): Returned code is other than sent
[2117] CONFIG (NumValues): Invalid number of values (must be 2)
[2127] CONFIG (NumValues): Invalid number of values (must be 5)
[2130] CONFIG (NumValues): Invalid number of values (must be 7)
[2194] CONFIG (NumValues): Too many values (max=2)
[2216] CONFIG (NumValues): Too many values (max=4)
[2223] CONFIG (NumValues): Too many values (max=5)
[3017] CONFIG (P0): Invalid device address (0-9)
[3508] CONFIG (P1): Invalid command
[4028] CONFIG (P2): Invalid code number (0-99)
[8190] CONFIG (Remote): Invalid command