Output format example (1) With ID number, date and time added
Function setting
(=Output Blank=No output)
5-td 1
Date/time
5-ed 3
Device
ID number
SV-1A/SV-1H output format example
Viscosity
/
Temper-
ature
Display Output format example Remarks
LLLLLmPas
LAB-12,2003/03/19,12:34:56,+025.67,C,+00000.00,mPa
s
Zeroes are output for
below measuring
range error.
0.30 mPas
LAB-12,2003/03/19,12:34:56,+025.67,C,+00000.30,mPa
s
10.0 mPas
LAB-12,2003/03/19,12:34:56,+025.67,C,+00010.00,mPa
s
100 mPas
LAB-12,2003/03/19,12:34:56,+025.67,C,+00100.00,mPa
s
1.00 Pas
LAB-12,2003/03/19,12:34:56,+025.67,C,+01000.00,mPa
s
For 1000 mPas or
greater, the displayed
unit is Pas, but the output
unit remains mPas.
mmPas
/
°C
H Pas
LAB-12,2003/03/19,12:34:56,+025.67,C,+01200.00,mPa
s
1200 is output for
above measuring
range error.
L Pas
LAB-12,2003/03/19,12:34:56,+051.23,F,+000.0000,
Pa s
Zeroes are output for
below measuring
range error.
0.0003 Pas
LAB-12,2003/03/19,12:34:56,+051.23,F,+000.0003,
Pa s
0.0100 Pas
LAB-12,2003/03/19,12:34:56,+051.23,F,+000.0100,
Pa s
0.100 Pas
LAB-12,2003/03/19,12:34:56,+051.23,F,+000.1000,
Pa s
1.00 Pas
LAB-12,2003/03/19,12:34:56,+051.23,F,+001.0000,
Pa s
Pas
/
°F
H Pas
LAB-12,2003/03/19,12:34:56,+051.23,F,+001.2000,
Pa s
1.2 is output for above
measuring range error.
L cP
LAB-12,2003/03/19,12:34:56,+025.67,C,+000.0000,
cP
Zeroes are output for
below measuring
range error.
0.30 cP
LAB-12,2003/03/19,12:34:56,+025.67,C,+00000.30,
cP
10.0 cP
LAB-12,2003/03/19,12:34:56,+025.67,C,+00010.00,
cP
100 cP
LAB-12,2003/03/19,12:34:56,+025.67,C,+00100.00,
cP
10.0 P
LAB-12,2003/03/19,12:34:56,+025.67,C,+01000.00,
cP
For 1000 cP or greater,
the displayed unit is
P, but the output unit
remains cP.
ccP
/
°C
H P
LAB-12,2003/03/19,12:34:56,+025.67,C,+01200.00,
cP
1200 is output for
above measuring
range error.
L P
LAB-12,2003/03/19,12:34:56,+051.23,F,+000.0000,
P
Zeroes are output for
below measuring
range error.
0.0030 P
LAB-12,2003/03/19,12:34:56,+051.23,F,+000.0030,
P
0.100 P
LAB-12,2003/03/19,12:34:56,+051.23,F,+000.1000,
P
1.00 P
LAB-12,2003/03/19,12:34:56,+051.23,F,+001.0000,
P
10.0 P
LAB-12,2003/03/19,12:34:56,+051.23,F,+010.0000,
P
P
/
°F
H P
LAB-12,2003/03/19,12:34:56,+051.23,F,+012.0000,
P
12 is output for above
measuring range error.
: Space (ASC 20h)
Outputs in the order of ID number, date, time,
temperature, temperature unit, viscosity and viscosit
y
unit.
The output data are 52 characters long excluding the
terminator.