A&D Multi Function Weighing Indicator AD-4402 Dokumentacja Strona 63

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 146
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 62
AD-4402 Page 61
7.4.
7.4.7.4.
7.4. C
CC
Customer
ustomer ustomer
ustomer P
PP
Program
rogramrogram
rogrammed
medmed
med
C
CC
Control
ontrolontrol
ontrol
(C
(C (C
(Comparison
omparison omparison
omparison Output
OutputOutput
Output)
))
)
The "customer programmed control mode" simply outputs the comparison results of
the setpoints and the displayed value.
The setpoint : A preset standard value to compare with the displayed value.
The comparison and output of the results are performed at each sampling time.
If this function is used, a PLC (programmable logic controller unit) is needed for batch
weighing on a hopper scale.
The power of the control I/O signal output is too small to drive a large valve directly.
Use relay output option ( OP-02 ) to drive them.
If the number of control I/O terminals is not enough, use the parallel I/O option ( OP-05 ).
Caution
Initial flow sequence and compensation sequence can not be used in the
"customer programmed control"
Advise
Automatic free fall compensation and Total function
If the start key is used, in the same as sequential mode, when three gates are closed, the
Eval timer has worked and the displayed value becomes stable, the batch finish signal
can be output.
The start key is not necessary to compare displayed values basically.
Przeglądanie stron 62
1 2 ... 58 59 60 61 62 63 64 65 66 67 68 ... 145 146

Komentarze do niniejszej Instrukcji

Brak uwag